mirror of
https://github.com/fjosw/pyerrors.git
synced 2025-03-16 15:20:24 +01:00
feat: Exception for gf coupling c!=0.3 added and documenation and tests
extended.
This commit is contained in:
parent
5cd20f5818
commit
638ec92ab7
2 changed files with 7 additions and 0 deletions
|
@ -569,6 +569,8 @@ def read_qtop(path, prefix, c, dtr_cnfg=1, version="openQCD", **kwargs):
|
||||||
def read_gf_coupling(path, prefix, c, dtr_cnfg=1, Zeuthen_flow=True, **kwargs):
|
def read_gf_coupling(path, prefix, c, dtr_cnfg=1, Zeuthen_flow=True, **kwargs):
|
||||||
"""Read the gradient flow coupling based on sfqcd gradient flow measurements. See 1607.06423 for details.
|
"""Read the gradient flow coupling based on sfqcd gradient flow measurements. See 1607.06423 for details.
|
||||||
|
|
||||||
|
Note: The current implementation only works for c=0.3 and T=L. The definition of the coupling in 1607.06423 requires projection to topological charge zero which is not done within this function but has to be performed in a separate step.
|
||||||
|
|
||||||
Parameters
|
Parameters
|
||||||
----------
|
----------
|
||||||
path : str
|
path : str
|
||||||
|
@ -600,6 +602,9 @@ def read_gf_coupling(path, prefix, c, dtr_cnfg=1, Zeuthen_flow=True, **kwargs):
|
||||||
(optional) If True, the Zeuthen flow is used for the coupling. If False, the Wilson flow is used.
|
(optional) If True, the Zeuthen flow is used for the coupling. If False, the Wilson flow is used.
|
||||||
"""
|
"""
|
||||||
|
|
||||||
|
if c != 0.3:
|
||||||
|
raise Exception("The required lattice norm is only implemented for c=0.3 at the moment.")
|
||||||
|
|
||||||
plaq = _read_flow_obs(path, prefix, c, dtr_cnfg=dtr_cnfg, version="sfqcd", obspos=6, sum_t=False, Zeuthen_flow=Zeuthen_flow, integer_charge=False, **kwargs)
|
plaq = _read_flow_obs(path, prefix, c, dtr_cnfg=dtr_cnfg, version="sfqcd", obspos=6, sum_t=False, Zeuthen_flow=Zeuthen_flow, integer_charge=False, **kwargs)
|
||||||
C2x1 = _read_flow_obs(path, prefix, c, dtr_cnfg=dtr_cnfg, version="sfqcd", obspos=7, sum_t=False, Zeuthen_flow=Zeuthen_flow, integer_charge=False, **kwargs)
|
C2x1 = _read_flow_obs(path, prefix, c, dtr_cnfg=dtr_cnfg, version="sfqcd", obspos=7, sum_t=False, Zeuthen_flow=Zeuthen_flow, integer_charge=False, **kwargs)
|
||||||
L = int(plaq.tag[2:])
|
L = int(plaq.tag[2:])
|
||||||
|
|
|
@ -104,3 +104,5 @@ def test_gf_coupling():
|
||||||
path = './tests//data/openqcd_test/'
|
path = './tests//data/openqcd_test/'
|
||||||
prefix = 'sfqcd'
|
prefix = 'sfqcd'
|
||||||
gf = pe.input.openQCD.read_gf_coupling(path, prefix, c=0.3)
|
gf = pe.input.openQCD.read_gf_coupling(path, prefix, c=0.3)
|
||||||
|
with pytest.raises(Exception):
|
||||||
|
pe.input.openQCD.read_gf_coupling(path, prefix, c=0.35)
|
||||||
|
|
Loading…
Add table
Reference in a new issue